NTP Server - SpecialPollTimeRemaining
the time provider ntpclient cannot reach or receiving invalid time data ntp2.usno.navy.mil (ntp.m|0x1|192.168.1.3:123->192.5.41.209:123).
after re-starting w32time service work 10-12 hours message appear once again in logs.
decided change ntp server time source following server: time.nrc.ca,0x1
my question following setting under ntpcleint in registry (specialpolltimeremaining). don't remember ever defining setting, showing old ntp server pointing "ntp2.usno.navy.mil,7baa8d8"
my question auto populate new 1 or can changed reflect new ntp external time source?
zt
check if there gpo configured time sync, if settings recreating option think gpo.
can find group policy settings used configure w32time in group policy object editor snap-in in following locations:
configure global configuration settings here.
computer configuration\administrative templates\system\windows time service
configure windows ntp client settings here.
computer configuration\administrative templates\system\windows time service\time providers
regards,
abhijit waikar - mcsa 2003|mcsa 2003:messaging|mcts|mcitp:sa
Windows Server > Directory Services
Comments
Post a Comment